Posts

Klargester Approved Stockist

Image
Waste Water Supplies are proud to announce we are a preferred and approved reseller/stockist of all Klargester products. There are more and more companies now advertising on the internet offering Klargester products but in fact have no buying terms with Klargester. This will lead them to offering you other manufacturers products and the company blaming high lead times and prices on Klargester, which in fact is false. If you require a Klargester product, make sure they are a Klargester approved Stockist or reseller before contacting the company concerned. Only companies approved by Klargester will have the new Klargester approved banner on their websites.

Klargester Car Wash Silt Trap

Image
The Klargester Car Wash Silt Trap is installed in areas with particularly high silt run-off, including vehicle or cash wash forecourts. A silt trap is designed to provide simple, effective separation and storage of silt to protect drainage systems. This is situated before a separator in car wash applications to ensure effective silt removal. Features and Benefits FACTA Class B Galvanised Covers Light an easy to install Maintenance from ground level Capacity 1,150 litres

Septic Tank Ban 2020

Image
New rules for septic tanks from 1st Jan 2020 From 1st January 2020 septic tanks are not allowed to discharge into the watercourse including ditches, streams, canals, rivers, surface water drains or any other type of watercourse. Under the new Environmental Agency "General Binding Rules" if you have a septic tank that discharges directly into surface water (as above examples) you MUST upgrade or replace them to a treatment plant by 1st Jan 2020 or if you sell your property before this date.(UK) All existing septic tanks that discharge into the watercourse will have to be replaced with a treatment plant that consents to BS EN 12566-3 certified. Or, discharge diverted to drainfield which consents to BS6297 2007. Also note that a drainage field is different from a soakaway which you can not use. Soakaways must be converted to drainage field or apply for a permit from the Environmental Agency to assess risks to groundwater. You sell your property - tell the new

Don't let your building plans go to waste - Ensure your choice of treatment plant is SR66 compliant

Image
We understand the pressures felt through your self build journey.   So when it comes to choosing your Klargester septic tank or Klargester sewage treatment plant, we need you to know the importance of choosing a Part H Building Control and SR66:2015 compliant solution.   At Kingspan, they've worked hard to ensure that their range of Klargester tanks for properties housing from 6 to 50 people are totally compliant with this new legislation (effective from January 2017). You know that when you choose a Klargester domestic sewage treatment plant or Klargester septic tank, which complies with SR66:2015, you are one step closer to getting that all-important sign-off on planning permission.

Soakaway Sizing

Image
https://www.wastewater-supplies.com/ Percolation test method Excavate a hole 300mm square to a depth 300mm below the proposed invert level of the soakaway pipes. Fill the 300mm square hole to at least the 300mm mark and allow to soakaway over night. On the next day, fill to the 300mm mark again and observe the time it takes to soakaway in seconds, from 70% full to 25% full. Divide the time taken by 150.  The answer gives you the average time in seconds (V). Carry out this test at least 3 times in at least 2 different places. Drain fields or soakaways should only be installed when the results are between 12 -100. If the value is outside these parameters you might need to install a sewage treatment plant. If you are unsure or need any further assistance please call us on 01923 260846 and we will be happy to help. Design And Construction Of The Soakaway The minimum size a soakaway should be constructed to is 30m. Soakaway

Clenviro - Matrix CLF1

Image
https://www.wastewater-supplies.com/products/clenviro-matrix-clf1 The Clenviro Matrix CLF1 will serve up to 6 people or 4 bedrooms Matrix sewage treatment systems are designed to optimise process efficiency, minimise running and maintenance costs and to be as simple and cost effective as possible to install. The MATRIX sewage treatment system is designed to achieve the minimum required effluent quality standard of 20mg/litre (BOD) : 30mg/litre (SS) : 20mg/litre Ammoniacal  The certified performance of the MATRIX system is that it produces an average final effluent quality of 11mg/litre (BOD) : 16mg/litre (SS) and 7mg/litre Ammoniacal. This relates to an average efficiency ratio of 96.2%, better than most other manufacturers. As part of the test procedure the MATRIX system was proven to have one of the lowest operating costs. All Matrix sewage treatment plants have a standard inlet invert depth, but in keeping with our commitment to customer satisfaction a

Mini Sewage Pumping Station 190S

Image
The mini 190S domestic sewage pumping station is a complete kit for use in areas where gravity flow is not available. The mini system is used for the transfer of sewage or waste water, all specially designed for easy installation. All our pumping stations comply to BS EN 12050-1:2001 / BS EN 752-6:1998 standards. The mini 190S is a small and compact sewage pumping station suitable for cellars, extensions, garden rooms and small applications. The standard pumping station consists of the heavy duty stainless steel Evak 50 (6m lift) submersible sewage pump with 50mm solid handling for peace of mind. This sewage pumping station can pump up to 80m across to mains   Mini 190S Sewage Pumping Station Includes: 1 x Evak 50mm solids sewage pump (up to 6m lift) 1 x 635mm x 610mm HDPE moulded basin 1 x 450mm dia Pedestrian rated cover (double seal) 1 x Soft close Non return valve 1 x Internal 2" PVC (class C) discharge pipe work